Services / Electrical Safety

Arc Flash Study & Electrical Safety Engineering

Arc flash events release intense heat, pressure and light in milliseconds, endangering people and plant. NOVTRIQ delivers arc flash studies that quantify incident energy across your electrical network, define safe working distances, and produce the labelling and PPE guidance operators need to work safely and stay compliant.

Discuss Your Project

What we deliver

  • Incident Energy Study Report: calculated incident energy (cal/cm2) at each equipment location, arc flash boundaries and working distances using the IEEE 1584 method
  • Protective Device Coordination Review: relay and breaker settings assessed to reduce arc duration and incident energy at source
  • Arc Flash Warning Labels: equipment-specific labels stating incident energy, boundary, required PPE category and shock-protection data
  • PPE Category Schedule: task-based PPE assignments aligned to NFPA 70E, with an arc-rated clothing and equipment matrix
  • Electrical Safety Programme Support: safe systems of work, lock-off and permit guidance, and energised work risk assessment input
  • DSEAR / Hazardous Area Input: coordination of arc flash controls with explosive-atmosphere requirements where relevant

Who it is for

  • Facilities and maintenance managers responsible for switchrooms, LV and HV distribution
  • Manufacturing, hospital and process operators carrying out energised work
  • Health and safety leads seeking defensible compliance with electrical safety duties

Standards & regulations

IEEE 1584NFPA 70EBS 7671:2018+A2:2022BS EN 60364 / IEC 60364DSEAR 2002Electricity at Work Regulations 1989IEC 60909HSG85

Method and modelling

We build a validated single-line model of the installation and run short-circuit and protection studies using industry platforms such as ETAP and SKM. Incident energy is calculated to IEEE 1584, with arc flash boundaries derived for each node. Where protection settings drive high incident energy, we recommend coordination changes, maintenance switching or arc-reduction measures to lower risk at source.

Labelling, PPE and safe working

Study outputs translate into practical controls: durable equipment labels, a task-based PPE schedule, and safe systems of work aligned to NFPA 70E principles and UK electrical safety duties. We advise on de-energised working as the primary control, and on the assessment required before any energised task proceeds.

Integration with wider electrical safety

Arc flash rarely sits alone. We coordinate findings with short-circuit ratings, earthing and bonding, and DSEAR requirements in hazardous areas, so that a single, consistent electrical safety picture supports both compliance and day-to-day operations.

How a project runs

1. Data collection. We gather single line diagrams, protective device settings, cable schedules and utility fault level data, and verify them on site where records are incomplete.

2. System model. We build the network model, run short circuit and protection coordination studies, and check that device settings clear faults as intended.

3. Incident energy calculation. We calculate arcing current and incident energy at each piece of equipment using the IEEE 1584 method, for each normal and alternative operating configuration.

4. Results and labels. We issue the report, arc flash boundaries, PPE categories and equipment labels, and highlight the locations where incident energy can be reduced by design.

5. Mitigation. Where values are high, we recommend measures such as faster protection settings, maintenance switching or remote racking, and recalculate to show the effect.

6. Review cycle. The study is reviewed whenever the system changes and at regular intervals, so labels and procedures stay valid.

Frequently asked questions

Is an arc flash study a legal requirement in the UK?

The Electricity at Work Regulations 1989 require employers to prevent danger from electrical systems, including arc flash. An arc flash study is the recognised way to quantify that risk and to set safe working arrangements, and many clients and insurers now require one.

What information do you need from us?

Up to date single line diagrams, protective device types and settings, cable sizes and lengths, transformer data and the fault level at the point of supply. Where records are missing, we collect the data on site.

How often should the study be updated?

Whenever the electrical system changes in a way that affects fault levels or protection, and at regular intervals as part of maintenance planning.

Ready to quantify and control arc flash risk?

NOVTRIQ delivers engineering-grade arc flash studies that make energised work safer and compliance defensible.

Discuss Your Project